Polybite Posterior Bite Registration Tray, 50/Box - Complete Buyer’s Guide

Polybite Posterior Bite Registration Tray, 50/Box - Complete Buyer’s Guide

Posterior
$14.76 USD
Sale price  $14.76 USD Regular price 
Skip to product information
Polybite Posterior Bite Registration Tray, 50/Box - Complete Buyer’s Guide

Dentamerica

Polybite Posterior Bite Registration Tray, 50/Box - Complete Buyer’s Guide

$14.76 USD
Sale price  $14.76 USD Regular price 

Free shipping

Easy returns

Safe checkout

Frequently bought together

Product overview

Inventory ID: 980-0937AA

Dentamerica Polybite posterior trays 50/box are disposable bite and impression trays designed to capture accurate posterior dental impressions, counter impressions, and bite registrations with a single versatile tray. The ergonomic design and reliable, rigid construction deliver consistent impression quality and streamlined clinical workflows. This Complete Buyer's Guide clarifies selection and maintains dependable posterior imaging and bite registration procedures.

What makes this product stand out?

Polybite trays are engineered as 3-in-one disposable trays that combine impression capture, counter impression, and bite registration in a single tray, reducing the need for multiple tray changes during clinical procedures. Their posterior-specific design delivers a comfortable fit around back teeth while maintaining dimensional stability and clear detail capture.

Key advantages include:

  • 3-in-one disposable tray handles impressions, counter impressions, and bite registrations in a single setup
  • Posterior shape improves fit and comfort for back-tooth capture
  • Rigid construction maintains tray shape for predictable results
  • The perforated design aids material retention and detail reproduction
  • 50/Box count delivers efficient operatory stocking and frequent use

What is this product made of?

Polybite posterior trays feature durable, rigid plastic that resists deformation while holding dental materials securely in place. Strong trays enable clinicians to achieve reliable impression capture and stable bite registration without unnecessary adjustments.

At-a-glance comparison:

  • Disposable plastic trays vs. reusable trays: disposable trays eliminate sterilization and cross-contamination concerns while maintaining infection control between patients
  • Posterior trays vs. full arch trays: posterior trays are sized to fit back tooth areas where smaller, more targeted impressions are needed

This material choice delivers hygienic, ready-to-use trays that standardize impression workflows and minimize setup time.

What is it used for?

Polybite posterior trays capture dental impressions and bite registrations in the posterior region, where accurate occlusal relationships and anatomical detail are essential for restorations, appliances, and diagnostic models.

Common applications include:

  • Posterior tooth impression capture for study models and diagnostic analysis
  • Bite registration for occlusal analysis and treatment planning
  • Counter impressions in crown and bridge workflows
  • Pre-treatment diagnostic impressions for restorative procedures
  • Orthodontic posterior impressions and occlusion recording

Why you'll appreciate this product

These trays deliver accurate impression capture, efficient bite registration, and smoother procedural flow.

For your work:

  • The 3-in-1 design handles multiple impression needs with fewer tray changes
  • Posterior shape improves comfort and fit around back teeth
  • Rigid construction maintains stable detail capture
  • Perforated design aids material retention
  • The disposable design delivers strong infection control

For your practice:

  • 50/Box packaging delivers predictable stocking
  • Easy tray use standardizes workflows across operatories
  • Reduced setup and cleanup delivers faster turnover
  • Consistent impression quality reduces retakes
  • Reliable and efficient performance benefits any practice

Reliable impression trays improve diagnostic accuracy, reduce chairside time, and deliver consistent restorative and orthodontic planning.

Specifications
  • Product type: Disposable bite and impression tray
  • Region: Posterior
  • Material: Rigid plastic
  • Design: Perforated for material retention
  • Function: 3-in-one for impression, counter impression, and bite registration
  • Count: 50/Box
  • Use: Single-use disposable
  • Compatibility: Impression materials suitable for plastic posterior trays (alginate, bite registration pastes)

Use trays as directed with compatible impression materials. Do not reuse disposable trays. Discard if trays are cracked, warped, or contaminated.

Sizing & selection

The right impression tray selection balances fit, patient comfort, and procedural efficiency.

Region selection:

Posterior trays focus on back tooth areas for detailed posterior capture and bite registration without full-arch coverage.

Material type:

Rigid plastic trays maintain dimensional accuracy under load. Perforated design aids material retention. Flexible trays may suit specific impression materials or patient comfort needs.

Disposable vs. reusable:

Disposable trays simplify infection control by eliminating cleaning and sterilization. Reusable trays may require more clinic time for processing.

Pack count and frequency:

A 50/box count ensures adequate trays for busy operatories without frequent restocking. Posterior trays have the highest count (50) compared to other sizes.

Posterior disposable trays deliver reliable clinical outcomes when hygiene, targeted capture, and consistent results matter.

Explore other options

Multiple impression and bite registration trays match clinical needs.

  • Polybite Anterior trays for front tooth impressions
  • Polybite Quadrant trays for smaller, sectional impressions
  • Polybite Full arch trays for complete arch impressions
  • Sideless trays for bite registration without impression capture
  • Tray liners and disposable handles for enhanced hygiene

Tailored tray selection matches impression scope, treatment type, and patient comfort for improved clinical outcomes and workflow efficiency.

Care & storage

Store trays properly to protect cleanliness and performance.

  • Store trays in a clean, dry area away from dust and moisture
  • Keep the box closed between uses
  • Remove trays chairside immediately before use
  • Dispose of used trays per office infection control and waste protocols
  • Do not attempt to sterilize and reuse disposable trays
Frequently asked questions
  1. Can these trays be used for bite registration and impressions?Yes. These Polybite trays combine impression capture, counter impression, and bite registration in a 3-in-one disposable tray.
  2. Are these trays disposable?Yes. They are single-use disposable trays that support infection control protocols between patients. Do not sterilize and reuse.
  3. What impression materials can be used with these trays?You can use them with a range of dental impression materials suited for plastic posterior trays, such as alginate and bite registration pastes.
  4. Do the trays capture posterior occlusal details accurately?Yes. The rigid posterior design with perforated surface provides good dimensional stability and detail for bite registration and impressions.
  5. How should I store unused trays?You should keep unused trays in their closed box, stored in a clean, dry area until needed chairside.

You may also like