Palodent Plus Sectional Matrix System Refill, 5.5 mm Matrices, 50/Pack - Complete Buyer’s Guide

Palodent Plus Sectional Matrix System Refill, 5.5 mm Matrices, 50/Pack - Complete Buyer’s Guide

5.5 mm / 50/Pack
$68.34 USD
Sale price  $68.34 USD Regular price 
Skip to product information
Palodent Plus Sectional Matrix System Refill, 5.5 mm Matrices, 50/Pack - Complete Buyer’s Guide

Dentsply

Palodent Plus Sectional Matrix System Refill, 5.5 mm Matrices, 50/Pack - Complete Buyer’s Guide

$68.34 USD
Sale price  $68.34 USD Regular price 

Free shipping

Easy returns

Safe checkout

Frequently bought together

Product overview

Inventory ID: 904-3383AA

Palodent Plus 5.5 mm refill matrices are sectional matrix bands designed to establish tight, anatomically correct contacts during posterior Class II composite restorations. These pre-contoured stainless steel bands feature pin tabs for secure placement and removal while minimizing overhang and finishing time. This Complete Buyer's Guide enables confident selection and supports consistent matrix protocols for predictable restorative outcomes.

What makes this product stand out?

These refill matrices are anatomically pre-contoured to replicate natural tooth shape and produce tight marginal seals during Class II posterior restorations. The 5.5 mm size suits wider posterior preparations, and the pin tab design enables precise placement and removal using Palodent Plus pin tweezers without additional instruments.

Key advantages include:

  • The pre-contoured design replicates natural tooth anatomy and pronounced marginal ridges
  • Pin tab construction enables precise placement and removal with pin tweezers
  • 5.5 mm size suits wider posterior preparations and embrasures
  • Stainless steel construction provides durable, autoclavable performance
  • 50/pack refill format supports efficient restocking within the existing system

What is this product made of?

Palodent Plus matrices are constructed from stainless steel with a pre-contoured profile designed to replicate natural posterior tooth anatomy. The autoclavable material maintains integrity through repeated sterilization cycles, while the anatomical shaping provides accurate marginal ridge height and contact point positioning during composite placement.

At-a-glance comparison:

  • Sectional matrices vs circumferential bands: sectional matrices provide more anatomically correct contacts and easier band adaptation to prepared teeth
  • Refill matrices vs complete kits: refill matrices maintain the existing Palodent Plus system without replacing rings, wedges, or instruments

For dental teams, this design supports consistent matrix performance and smoother restorative procedures across a range of posterior cases.

What is it used for?

Palodent Plus 5.5 mm refill matrices are used to shape and contain composite material during posterior Class II restorations, forming tight proximal contacts and accurate contours while restorative material is placed and cured. The matrices work in combination with Palodent Plus nickel-titanium rings, wedges, and wedge guards to complete the sectional matrix system.

Common applications include:

  • Shaping composite during Class II restorations for posterior teeth
  • Forming tight interproximal contacts and marginal seals
  • Stabilizing restorative material during incremental composite placement
  • Creating accurate emergence profiles and natural contours
  • Reducing overhang and finishing time through pre-contoured design

Why you'll appreciate this product

These matrices produce tight contacts and accurate anatomy while keeping restorative workflows efficient across your team.

For your work:

  • The pre-contoured design replicates natural tooth anatomy and marginal ridges
  • The pin tab enables precise placement and removal with pin tweezers
  • 5.5 mm size covers a wide range of posterior preparations
  • Autoclavable stainless steel provides reliable, reusable sterilization

For your practice:

  • 50/pack refill format supports organized restocking and inventory planning
  • Compatibility with existing Palodent Plus components reduces system cost
  • Consistent anatomy replication reduces finishing time per restoration
  • Standard size supports predictable technique across operatories

Reliable matrix shaping supports accurate contacts, reduced finishing time, and confident restorative outcomes.

Specifications
  • Product type: Sectional matrix band refill
  • Size: 5.5 mm
  • Material: Stainless steel
  • Design: Pre-contoured with pin tab
  • Count: 50/pack
  • Sterilization: Autoclavable
  • Use: Composite shaping during Class II posterior restorations
  • Compatibility: Palodent Plus sectional matrix system (rings, wedges, wedgeguards, pin tweezers, forceps)
  • Available sizes: 3.5 mm, 4.5 mm, 5.5 mm, 6.5 mm, 7.5 mm

Inspect matrices before use and discard any that are bent, deformed, or compromised. Use only as part of the compatible Palodent Plus sectional matrix system, and follow the manufacturer's technique guidelines for placement and removal.

Sizing & selection

Selecting the correct matrix size supports accurate contacts, tight marginal seals, and reduced finishing time.

Matrix size selection:

The 5.5 mm size suits wider posterior preparations where greater band height is needed to achieve proper marginal ridge height and contact formation. Smaller sizes, such as 3.5 mm or 4.5 mm, may be more appropriate for narrower preparations or limited access areas.

System compatibility:

These refill matrices are designed specifically for the Palodent Plus sectional matrix system. Using compatible rings, wedges, and wedge guards ensures proper seating, accurate separation, and a tight gingival seal.

Preparation depth:

Standard matrices cover most posterior preparations effectively. For deeper preps, Palodent Plus offers 6.5 mm and 7.5 mm matrices with gingival aprons designed to seal without causing gingival trauma.

Placement technique:

The pin tab on each matrix enables secure grasping with Palodent Plus pin tweezers for controlled placement and removal. Following the manufacturer's technique guidelines supports predictable contact outcomes.

Palodent Plus 5.5 mm matrices support accurate contacts and tight marginal seals when reliable restorative shaping matters.

Explore other options

Many practices keep a range of Palodent Plus matrix components to match tooth anatomy and preparation needs.

  • 3.5 mm and 4.5 mm matrices for narrower posterior preparations
  • 6.5 mm and 7.5 mm matrices with gingival aprons for deeper preparations
  • Nickel-titanium ring refills (universal and narrow) for separation
  • Medium wedge refills and guards for gingival sealing

Tailoring matrix supplies to preparation depth, tooth anatomy, and clinician preference supports predictable contacts and efficient workflows.

Care & storage

Store refill matrices properly to protect cleanliness and readiness.

  • Store in a clean, dry area to prevent contamination
  • Keep the packaging sealed between uses
  • Open matrices chairside only as needed for each case
  • Discard bent or deformed matrices promptly
  • Dispose of used components according to office protocols
Frequently asked questions
  1. What are these matrices used for?You can use them to shape and contain composite material during Class II posterior restorations, forming tight contacts and accurate tooth contours.
  2. Will these matrices work with my existing Palodent Plus system?Yes, they are designed as refill matrices for the Palodent Plus system and are compatible with Palodent Plus rings, wedges, wedgeguards, pin tweezers, and forceps.
  3. How do I choose the right size?You should select the 5.5 mm size for wider posterior preparations. For narrower preps, consider 3.5 mm or 4.5 mm; for deeper preps, 6.5 mm or 7.5 mm options with gingival aprons are available.
  4. Can damaged matrices be reused?No, you should discard any bent or deformed matrices to maintain accurate contact formation and consistent performance.
  5. How do I place and remove these matrices?You should use Palodent Plus pin tweezers to grasp the pin tab on each matrix for controlled placement and removal during the restoration procedure.

You may also like