{"product_id":"cytoflex-resorb-20mmx25mm-asorbable-pla-pga-gtr-membrane-1-per-box","title":"Cytoflex Resorb 20mmx25mm, Asorbable PLA\/PGA, GTR membrane,1 per box","description":"\u003cul id=\"ItemBullet\"\u003e\n\u003cli\u003eSynthetic PLA\/PGA; 100% biocompatible and biodegradable\u003c\/li\u003e\n\u003cli\u003e0.35mm thickness; textured surface for cell adhesion\u003c\/li\u003e\n\u003cli\u003eBarrier function maintained approx. 2 months\u003c\/li\u003e\n\u003cli\u003eFull resorption at 6 months; no secondary surgery\u003c\/li\u003e\n\u003cli\u003eSized for localized defects and single-tooth sockets\u003c\/li\u003e\n\u003cli\u003eQuantity: 1 per Box, 20mm x 25mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cp id=\"LongDesc\" class=\"richp\"\u003eUnicare Cytoflex Resorb Absorbable GTR\/GBR Barrier Membrane, PLA\/PGA, 20mm x 25mm is used for guided tissue regeneration and guided bone regeneration in localized periodontal defects, single-tooth extraction socket preservation, anterior implant fenestration and dehiscence coverage, and smaller intrabony defect sites where a compact membrane dimension provides precise coverage without the excess trimming that larger membrane formats require at contained or single-site surgical presentations. Periodontists, oral surgeons, and implant dentists managing localized regenerative cases find the 20mm x 25mm format well matched to single-site procedures where the larger 30mm x 40mm membrane would require significant trimming before placement.\n?\nEach box contains one membrane measuring 20mm x 25mm, constructed from synthetic PLA\/PGA copolymer with a textured surface and a uniform thickness of 0.35mm.\u003cbr\u003e\u003cbr\u003eThe compact dimension provides defect-appropriate coverage at single-tooth sites without material surplus. The 0.35mm thickness provides the structural rigidity needed to maintain space over the defect without soft tissue collapse during the early healing phase while remaining conformable enough to adapt to the variable bone surface topography and defect geometry encountered at localized implant and periodontal sites. The textured surface promotes host cell adhesion on the tissue-facing side, supporting the cellular attachment and neo-vascularization activity that contribute to organized tissue regeneration within the protected defect space during the barrier function period.\n?\nThe 20mm x 25mm Cytoflex Resorb membrane degrades through the Unicare water method, the same hydrolysis-based resorption process that governs all Cytoflex Resorb formats regardless of size.\u003cbr\u003e\u003cbr\u003eWater penetrates the PLA\/PGA polymer matrix and breaks down the copolymer bonds progressively, maintaining barrier function for approximately two months before the degradation rate accelerates and complete resorption is achieved at approximately six months post-placement. The degradation byproducts, water and carbon dioxide, are metabolized through normal physiological pathways without producing inflammatory byproducts or requiring clinical intervention during the resorption phase. The absence of animal-derived components in the synthetic PLA\/PGA formulation eliminates the disease transmission considerations and biocompatibility variables associated with collagen membranes, providing a fully defined material profile that supports consistent, predictable regenerative outcomes across diverse patient populations and defect types.\n?\nImplant dentists placing membranes at single-tooth extraction sites for socket preservation prior to implant placement find the 20mm x 25mm format provides accurate defect coverage at contained sites where the larger format would produce unusable remnant membrane material after trimming.\u003cbr\u003e\u003cbr\u003ePeriodontists managing isolated intrabony defects, class II furcation defects, and recession-associated bone defects find the compact membrane dimension well matched to the localized treatment zone without requiring the extensive trimming that larger formats demand at single-site presentations.\n?\nUnicare Cytoflex Resorb Absorbable GTR\/GBR Barrier Membrane, 20mm x 25mm gives periodontal and implant surgical practices a compact-format resorbable membrane that covers localized regenerative defect presentations efficiently, maintains a defined barrier function period, and resorbs completely without secondary surgical intervention. For practices ordering resorbable GTR membrane supplies, the 20mm x 25mm PLA\/PGA Cytoflex Resorb provides the right dimension for single-site cases where precise, waste-free membrane coverage is the surgical priority.\u003c\/p\u003e","brand":"Unicare","offers":[{"title":"Default Title","offer_id":47373807943858,"sku":"UNI-C03-0201","price":91.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/7747\/2690\/files\/137111_main.webp?v=1777662782","url":"https:\/\/beyond.frontierdental.com\/products\/cytoflex-resorb-20mmx25mm-asorbable-pla-pga-gtr-membrane-1-per-box","provider":"Beyond","version":"1.0","type":"link"}